Korean J Lab Med. Jun;27(3) [Evaluation of the Abbott Cell-Dyn Sapphire hematology analyzer]. [Article in Korean]. Park Y(1), Song J, Song S. Name of instrument, CELL-DYN Sapphire*. First year installed in U.S./Outside U.S./No. of units sold in , //—. No. units installed in U.S./Outside. The CELL-DYN Sapphire hematology system is designed to address routine testing needs of high-volume hematology laboratories and difficult.

Author: Nikasa Shakashicage
Country: Romania
Language: English (Spanish)
Genre: Literature
Published (Last): 6 February 2011
Pages: 113
PDF File Size: 19.95 Mb
ePub File Size: 8.86 Mb
ISBN: 418-2-91684-143-2
Downloads: 29216
Price: Free* [*Free Regsitration Required]
Uploader: Kik

[Evaluation of the Abbott Cell-Dyn Sapphire hematology analyzer].

Leukocyte counts in cerebrospinal fluid with the automated haematology analyzer CellDyn and the urine flow cytometer UF Cell-Dyn from Cell Dyn Sapphire. For questions about using the LabWrench web site please call us.

AWBC count: Because hematology analyzers are normally running blood samples with inherently much higher cell concentrations, the accepted background cell concentration and the elimination of carryover are important issues. Each dilution was examined 10 times.

The parameters of the regression equation are summarized in Table 3.

The Cell-Dyn Sapphire flagged 7 samples, but in only 2 of those samples were metastatic cells present according to the differentiation of the cytocentrifuged preparation. Comparison between Cell-Dyn to Cell-Dyn Sapphire Please could you kindly explain in brief the differences between the two Machines Products are available for international distribution only unless otherwise indicated.

The names and logos of manufacturers, their instruments, and their products referred to herein may be protected by trademark or other law, and are used herein solely for purpose of reference. BMononuclear cells with the cytocentrifuged preparation possibly including epithelial cells and macrophages. We investigated whether these limits can be modified to make them applicable for body fluids with much lower cell concentrations compared with blood.

  INTELLIMATCH SUNGARD PDF

In 10 samples of serous fluids, metastatic cells were detected with microscopic NC differentiation of the cytocentrifuged preparation.

On the other hand, the Cell-Dyn Sapphire failed to flag the remaining 8 samples with metastatic cells.

Inquire Here Reagent Type: In the present article, we describe its applicability for the distinct body fluids, and we highlight limitations and caveats. Statistical analyses were performed with Analyse-it software, version 1.

The parameters of the regression equation are summarized in Table 2. For assessing the differential count, the percentages of lymphocytes and monocytes determined by the Cell-Dyn Sapphire were added, and this sum was compared with the mononuclear cell MNC count found on the cytocentrifuged preparations, which included lymphocytes, monocytes, and, in some samples, epithelial cells and macrophages.

Up to sample autoloader and open vial sample handling. The within-run imprecision of the microscopic NC count at low cell counts was comparable to that of the automated method and ranged from The positive and negative likelihood were respectively 3. View large Download slide.

Abbott Diagnostics CELL-DYN Sapphire® | Forums | Questions | Discussions | Help | LabWrench

RBC counts are important for the diagnosis of intracerebral hemorrhage and for the exclusion of a traumatic tap as the cause of an elevated WBC count. Inquire Here Point Of Care: Inquire Here Reagent System: Request Pricing Receive your quote directly from the manufacturer.

  LASER CLASS 2060P PDF

The history of Abbott’s Diagnostics Division is an impressive record of babott.

Close mobile search navigation Article navigation. Within-run imprecision of the microscopic NC count was also investigated at low cell counts. Moreover, the inability to detect malignant cells or other pathologic cell types eg, cell clusters and extracellular and intracellular bacteria strongly justifies the need aapphire sustained visual morphologic examination of cytocentrifuged preparations.

Citing articles via Web of Science Receive your quote directly from the manufacturer. For current regulatory status on products within this website, abboty contact your sales representative.

CELL-DYN Sapphire Hematology Analyzer from Abbott | SelectScience

Two Extraordinary Sellar Neuronal Tumors: Specifications Private Labeled by: The Cell-Dyn Sapphire is an automated hematology analyzer designed for counting peripheral blood sa;phire in whole blood samples. Abbott products have helped transform the practice of medical For method comparison, we used CSF, serous fluid 61 pleural and 40 peritonealand CAPD fluid samples that were collected for routine diagnostic purposes.

We evaluated the analytic and clinical performance of the Cell-Dyn Sapphire for blood cell counting and WBC differential count in body fluids.

Prices and Information shown are for reference only and may change without notice. Inquire Here Auto Sample Handling: